Roof & Septic

How we calculate

The formula, the assumptions and the sources behind every answer.

Roof pitch

  1. Pitch is the rise, in inches, for every 12 inches of run.
  2. Degrees = atan(pitch ÷ 12).
  3. Slope multiplier = √(12² + pitch²) ÷ 12.

Assumes: The roof is a single flat slope, and the run is measured level.

Sources: This is geometry, so it needs no source.

Last reviewed 18 November 2026

Open the calculator

Rafter length

  1. Run = half the building width, less half the thickness of the ridge board.
  2. Slope multiplier = √(12² + pitch²) ÷ 12.
  3. Rafter to the wall = run × multiplier.
  4. Tail = overhang × multiplier.
  5. Full length = (half the width − half the ridge board) × multiplier + overhang × multiplier.

Assumes: A common rafter on a gable or shed roof, measured along the top edge.

Sources: This is geometry, so it needs no source.

Last reviewed 18 November 2026

Open the calculator

Roof area

  1. Footprint = the building length × width, including the overhang.
  2. Slope multiplier = √(12² + pitch²) ÷ 12.
  3. Roof area = footprint × multiplier.
  4. One square = 100 sq ft, so squares = area ÷ 100.

Assumes: The roof has no hips, valleys or dormers unless you add them.

Sources: This is geometry, so it needs no source.

Last reviewed 18 November 2026

Open the calculator

Shingles

  1. Start from the roof area in squares, with the waste allowance added.
  2. Bundles = squares × bundles per square.
  3. Round up to a whole bundle.

Assumes: The bundles per square come from the shingle you choose, and the waste allowance is a number you can change.

Sources: Bundles per square are printed on the shingle packaging, so check yours.

Last reviewed 18 November 2026

Open the calculator

Septic tank size

  1. 1,000 gallons for up to 3 bedrooms.
  2. Add 250 gallons for each bedroom after the third.
  3. This is a planning figure, not any one state's rule. New York's table matches it; most states we checked ask for the same or a little less, and Massachusetts and Ohio ask for more.
  4. If you pick a state, the answer is that state's own minimum for the bedrooms, read from its rule and not worked out by us.

Assumes: The size is set by bedrooms. Your state or county may use a different table, or ask for more.

Sources: The septic rules of 15 states, each linked from the table on the calculator page, and the tank table in the U.S. EPA's Onsite Wastewater Treatment Systems Manual (2002). Read on 18 November 2026.

Last reviewed 18 November 2026

Open the calculator

Drain field size

  1. Daily flow = bedrooms × gallons a day per bedroom.
  2. Drain field area = daily flow ÷ soil loading rate.
  3. The soil loading rate, in gallons per square foot per day, comes from your soil.

Assumes: The soil rate comes from a perc test or soil evaluation. Your county decides the number it accepts.

Sources: The U.S. EPA's Onsite Wastewater Treatment Systems Manual (2002) for the method and the 150 gallons a day for each bedroom, and the rules of 15 states, each linked from the table on the calculator page. Read on 18 November 2026.

Last reviewed 18 November 2026

Open the calculator

What changes, and when

When we fix a mistake or a rule changes, we update the page and add a line to the changelog saying what changed and when.

Found something wrong on this page? Report a wrong answer