Drain field size calculator
The absorption area and trench length for your soil.
You need a soil rate to get an answer.
A drain field is sized from how fast your soil takes water, and that number comes from a perc test or a soil evaluation. We never guess a rate for you.
For homes in the United States. This page uses US state rules, US gallons and feet. Its answers do not apply in Canada, the UK, Australia or anywhere else.
The words on your soil report, explained
Loading rate. How many gallons of water a day each square foot of trench bottom can take. A higher number means the soil takes water faster, so you need less area.
Perc rate. The result of a perc test: how many minutes it takes water to drop one inch in a test hole. A higher number means slower soil. It is not a loading rate. The EPA's design manual says a soil's structure and texture predict how much water it can take better than a perc test does, and most states now look at the soil itself as well. Where a perc rate is still used, the state's own table turns it into a field size.
Absorption area. The total area of trench bottom that soaks the water in. It is the daily flow divided by the loading rate.
How the size is worked out
Three steps. First, the daily flow: bedrooms times the gallons a day for each bedroom. Second, the absorption area: that flow divided by the soil's loading rate. Third, the trench length: that area divided by how wide you dig the trenches.
A worked example: 3 bedrooms × 150 gallons is 450 gallons a day. With a loading rate of 0.6, the area is 450 ÷ 0.6 = 750 sq ft. In trenches 3 ft wide, that is 750 ÷ 3 = 250 ft of trench. The rate of 0.6 is an example, not your soil.
Daily flow and trench width, by state
The calculator starts at 150 gallons a day for each bedroom, which the EPA's design manual calls a commonly assumed figure. The states we checked mostly use 110, 120 or 150, and a few use a table of their own. To use your state's figure, open "More" under the questions.
| State | Daily flow the rule uses | Trench width | The rule |
|---|---|---|---|
| Alabama | 150 gallons a day for each bedroom | 18 to 36 inches | Ala. Admin. Code ch. 420-3-1 |
| California | 250 gallons a day for a house in the state policy. Counties set the figure per bedroom. | No wider than 3 feet | State Water Board OWTS Policy, with the California Plumbing Code, Appendix H |
| Florida | 100 gallons a day for each bedroom up to 4, then 60 for each extra bedroom | No wider than 36 inches | Fla. Admin. Code ch. 62-6 |
| Georgia | A trench area for each bedroom that depends on the perc rate. 150 gallons a day per bedroom for alternative systems. | No wider than 36 inches | Ga. Comp. R. & Regs. ch. 511-3-1 |
| Indiana | 150 gallons a day for each bedroom | 18 to 36 inches | 410 IAC 6-8.3 |
| Massachusetts | 110 gallons a day for each bedroom, and at least 330 for a house | 2 to 3 feet | 310 CMR 15.000 (Title 5) |
| Michigan | Set by the local health department | – | State septic program |
| New York | 110 gallons a day for each bedroom with fixtures from 1994 or later, and 130 or 150 with older ones | Designed as 24 inches wide at most | 10 NYCRR Appendix 75-A |
| North Carolina | 120 gallons a day for each bedroom | 2 to 3 feet | 15A NCAC 18E |
| Ohio | 120 gallons a day for each bedroom, and at least 240 | – | Ohio Admin. Code ch. 3701-29 |
| Pennsylvania | 400 gallons a day for up to 3 bedrooms, then 100 for each extra bedroom | 12 to 72 inches | 25 Pa. Code chs. 72 and 73 |
| Tennessee | No gallons figure. Where a perc test sizes the field, at least 370 square feet of trench bottom for each bedroom. | – | Tenn. Comp. R. & Regs. 0400-48-01 |
| Texas | A table by bedrooms and floor area: 225 to 525 gallons a day for a house | – | 30 Tex. Admin. Code ch. 285 |
| Virginia | 75 gallons a day for each person, at two people to a bedroom, which is 150 a bedroom | 18 to 36 inches for gravity trenches | 12VAC5-610 |
| Washington | 120 gallons a day for each bedroom, and at least 240 | 3 feet or less | WAC 246-272A |
Common questions
Why won't you suggest a soil rate?
Because it depends on your soil, and a wrong guess means a field that fails or one that costs far more than it should. Get the rate from a perc test or a soil evaluation.
Can I split the trench into several runs?
Usually, yes. The total length is split into runs, and the layout has to fit your lot and be approved by your county. The designer sets it.
Does a wider trench mean a shorter one?
For the same area, yes. A trench twice as wide needs half the length. State rules cap the width: 18 to 36 inches in Alabama, Indiana and Virginia, 2 to 3 feet in Massachusetts and North Carolina, and 12 to 72 inches in Pennsylvania. The EPA's design manual prefers narrower trenches.
- U.S. EPA, Onsite Wastewater Treatment Systems Manual (2002), pages 3-19, 4-12 and 4-14: the method, the 150 gallons a day for each bedroom, perc tests against soil evaluations, and trench widths
- The state rules linked in the table above: each state's daily flow and trench width
Sources last checked 18 November 2026.
Related
Last reviewed 18 November 2026 · How we calculate · Report a wrong answer