Roof & Septic

Drain field size calculator

The absorption area and trench length for your soil.

You need a soil rate to get an answer.

A drain field is sized from how fast your soil takes water, and that number comes from a perc test or a soil evaluation. We never guess a rate for you.

Don't have a soil rate? What a perc test is

Your numbers

How many bedrooms?
trench bottomwater soaks inground levelgallons per square foot a day

It comes from your perc test or soil report. Leave it empty until you have it.

I have a perc rate in minutes per inch instead

A perc rate and a loading rate are not the same number. Each state has its own table for turning a perc rate into a loading rate, so ask the health department or the soil evaluator for the loading rate. Read the perc test guide

feet
More: daily flow per bedroom
gallons a day

150 is the figure the EPA's design manual calls commonly assumed. The states we checked mostly use 110, 120 or 150. See your state

For homes in the United States. This page uses US state rules, US gallons and feet. Its answers do not apply in Canada, the UK, Australia or anywhere else.

The words on your soil report, explained

Loading rate. How many gallons of water a day each square foot of trench bottom can take. A higher number means the soil takes water faster, so you need less area.

Perc rate. The result of a perc test: how many minutes it takes water to drop one inch in a test hole. A higher number means slower soil. It is not a loading rate. The EPA's design manual says a soil's structure and texture predict how much water it can take better than a perc test does, and most states now look at the soil itself as well. Where a perc rate is still used, the state's own table turns it into a field size.

Absorption area. The total area of trench bottom that soaks the water in. It is the daily flow divided by the loading rate.

How the size is worked out

Three steps. First, the daily flow: bedrooms times the gallons a day for each bedroom. Second, the absorption area: that flow divided by the soil's loading rate. Third, the trench length: that area divided by how wide you dig the trenches.

A worked example: 3 bedrooms × 150 gallons is 450 gallons a day. With a loading rate of 0.6, the area is 450 ÷ 0.6 = 750 sq ft. In trenches 3 ft wide, that is 750 ÷ 3 = 250 ft of trench. The rate of 0.6 is an example, not your soil.

Daily flow and trench width, by state

The calculator starts at 150 gallons a day for each bedroom, which the EPA's design manual calls a commonly assumed figure. The states we checked mostly use 110, 120 or 150, and a few use a table of their own. To use your state's figure, open "More" under the questions.

Read in each state's own rule and checked on 18 November 2026. Counties and towns can be stricter. A dash means the rule we read gives no single width.
StateDaily flow the rule usesTrench widthThe rule
Alabama150 gallons a day for each bedroom18 to 36 inchesAla. Admin. Code ch. 420-3-1
California250 gallons a day for a house in the state policy. Counties set the figure per bedroom.No wider than 3 feetState Water Board OWTS Policy, with the California Plumbing Code, Appendix H
Florida100 gallons a day for each bedroom up to 4, then 60 for each extra bedroomNo wider than 36 inchesFla. Admin. Code ch. 62-6
GeorgiaA trench area for each bedroom that depends on the perc rate. 150 gallons a day per bedroom for alternative systems.No wider than 36 inchesGa. Comp. R. & Regs. ch. 511-3-1
Indiana150 gallons a day for each bedroom18 to 36 inches410 IAC 6-8.3
Massachusetts110 gallons a day for each bedroom, and at least 330 for a house2 to 3 feet310 CMR 15.000 (Title 5)
MichiganSet by the local health department–State septic program
New York110 gallons a day for each bedroom with fixtures from 1994 or later, and 130 or 150 with older onesDesigned as 24 inches wide at most10 NYCRR Appendix 75-A
North Carolina120 gallons a day for each bedroom2 to 3 feet15A NCAC 18E
Ohio120 gallons a day for each bedroom, and at least 240–Ohio Admin. Code ch. 3701-29
Pennsylvania400 gallons a day for up to 3 bedrooms, then 100 for each extra bedroom12 to 72 inches25 Pa. Code chs. 72 and 73
TennesseeNo gallons figure. Where a perc test sizes the field, at least 370 square feet of trench bottom for each bedroom.–Tenn. Comp. R. & Regs. 0400-48-01
TexasA table by bedrooms and floor area: 225 to 525 gallons a day for a house–30 Tex. Admin. Code ch. 285
Virginia75 gallons a day for each person, at two people to a bedroom, which is 150 a bedroom18 to 36 inches for gravity trenches12VAC5-610
Washington120 gallons a day for each bedroom, and at least 2403 feet or lessWAC 246-272A

Common questions

Why won't you suggest a soil rate?

Because it depends on your soil, and a wrong guess means a field that fails or one that costs far more than it should. Get the rate from a perc test or a soil evaluation.

Can I split the trench into several runs?

Usually, yes. The total length is split into runs, and the layout has to fit your lot and be approved by your county. The designer sets it.

Does a wider trench mean a shorter one?

For the same area, yes. A trench twice as wide needs half the length. State rules cap the width: 18 to 36 inches in Alabama, Indiana and Virginia, 2 to 3 feet in Massachusetts and North Carolina, and 12 to 72 inches in Pennsylvania. The EPA's design manual prefers narrower trenches.

Where this comes from

Sources last checked 18 November 2026.

Related

Last reviewed 18 November 2026 · How we calculate · Report a wrong answer